OS GSO ISO/TS 4869-5:2014
ISO/TS 4869-5:2006
Omani Standard
Current Edition
·
Approved on
25 December 2014
Acoustics -- Hearing protectors -- Part 5: Method for estimation of noise reduction using fitting by inexperienced test subjects
OS GSO ISO/TS 4869-5:2014 Files
English
18 Pages
Current Edition
Reference Language
Obtaining this standard through the store is currently unavailable. You can acquire it directly from its source.
OS GSO ISO/TS 4869-5:2014 Scope
This Technical Specification specifies a method for measuring noise reduction of passive hearing protectors at the threshold of hearing. The method is designed to provide estimates of the noise reduction obtained by typical groups of users in real-world occupational settings, who may lack the training and motivation to wear hearing protectors in an optimum manner.
The principle of the test method is to measure the difference in hearing threshold with and without wearing a hearing protector. This difference between the thresholds constitutes the noise reduction. The measurement is done twice on a given number of test subjects.
NOTE 1 The principle of measuring the influence of a hearing protector on the hearing threshold is used in ISO 4869-1 and in this Technical Specification. The method described in ISO 4869-1 yields the sound attenuation of the hearing protector under test. The result of the measurement is a pure physical characteristic of the hearing protector. The method described in this Technical Specification yields the performance of the system as a whole, i.e. the influence of hearing protector, test subjects, fitting and instruction.
This test method yields data that are collected at low sound pressure levels (close to the threshold of hearing), but which are also representative of the noise reduction values of hearing protectors at higher sound pressure levels. This Technical Specification is inapplicable for level-dependent hearing protectors for sound pressure levels above the point at which their level-dependent characteristics become effective.
NOTE 2 At frequencies below 500 Hz, real-ear noise reduction data measured according to this Technical Specification may be spuriously high by a few decibels, with the error increasing as the frequency decreases. The error results from masking of the occluded-ear threshold by physiological noise during testing.
Best Sellers From Metrology Sector
OS GSO OIML R87:2021
OIML R87:2016
Omani Standard
Quantity of product in prepackages
GSO OIML R87:2021
OIML R87:2016
Gulf Standard
Quantity of product in prepackages
GSO OIML R79:2021
OIML R79:2015
Gulf Standard
Labeling requirements for prepackages
OS GSO OIML R79:2021
OIML R79:2015
Omani Standard
Labeling requirements for prepackages
Recently Published from Metrology Sector
GSO ISO 16610-31:2026
ISO 16610-31:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 31: Robust profile filters: Gaussian regression filters
GSO ISO 23783-2:2026
ISO 23783-2:2022
Gulf Standard
Automated liquid handling systems — Part 2: Measurement procedures for the determination of volumetric performance
GSO ISO 16610-45:2026
ISO 16610-45:2025
Gulf Standard
Geometrical product specifications (GPS) — Filtration — Part 45: Morphological profile filters: Segmentation
GSO ISO 4064-1:2026
ISO 4064-1:2024
Gulf Standard
Water meters for cold potable water and hot water — Part 1: Metrological and technical requirements